Access Tile Tactile System

The official website for Access Tile USA.

Access Tile Tactile System
The Ultimate Solution® in Detectable Warning Systems
1-888-679‐4022
Access Tile: MAde in USA

ACCESS® TILE is designed, tested and manufactured in the U.S.A

  • Products
    • Replaceable Cast In Place
    • Surface Applied
    • Wayfinding
    • Radius Curve
    • Product Warranty
    • Quote Request
  • ADA Resources
    • Radius Calculator
    • ADA Regulations
    • Specifications & Technical
    • Installation & Maintenance
    • Material Safety Data Sheets
    • Catalog
    • Submittal Package
    • Certificates
    • Warranty
    • Blog
  • Tactile Gallery
    • Replaceable Cast in Place Gallery
    • Surface Applied Gallery
    • Wayfinding Tiles Gallery
    • Radius Curve Gallery
  • Testimonials
  • FAQ
    • The Top 20 FAQ
    • ADA Curb Ramps
    • Affordable tactile
    • Non-Slip Tactile
    • Benefits
    • High Definition
    • Trip Hazard Protection
    • Truncated Dome Spacing
  • Contact
    • Our Locations
    • Distributors

Specification and Technical Drawing

For your convenience we have placed all specifications and technical drawings for our truncated dome tiles on this page. We have divided these resources by Replaceable Cast in Place tile and Surface Applied tile, although there are some commonalities between the two. Below you will find the colors available for all of our tactile paving, as well as all the different sizes. It is important to note, however, that all of our detectable warning tiles can be cut to fit in any space; this can be done without voiding the Product Warranty.

Every Access® Tile ADA compliant tile is tested rigorously to ensure it is durable and long-lasting, using a series of AASHTO tests, ASTM concrete tests, and ASTM D tests. This information can be found in the characteristics table.

Available Sizes

Tile Sizes

Available Colors

Ochre Yellow (OCR)
FED 23594
Federal Yellow(YW)
FED 33538 / RAL 1003
Safety Red(SR)
FED 31350
Colonial Red(COL)
FED 20109 / RAL 8012
Brick Red (RD)
FED 22144 / RAL 3016
Ocean Blue(BL)
FED 15187 / RAL 2486
Bright White(WH)
FED 27925
Light Gray(LG)
FED 26280
Dark Gray (DG)
FED 36118 / RAL 2486
Onyx Black (BK)
FED 17038 / RAL 9005

Replaceable Cast in Place Tiles

Replaceable Cast in Place Specifications

Part No.Standard SizesWeightBox QualityAnchors Included
ACC-R-1212-XX
1' X 1'5 lbs. (2 kg)104
ACC-R-2424-XX2' X 2'9 lbs. (4 kg)109
ACC-R-2436-XX
2' X 3'12 lbs. (5 kg)1012
ACC-R-2448-XX
2' X 4'13 lbs. (7 kg)1013
ACC-R-2460-XX
2' X 5'18 lbs. (9 kg)1018
ACC-R-3648-XX
3' X 4'24 lbs. (11 kg)1018
ACC-R-3660-XX
3' X 5'31 lbs. (13 kg)1024
ACC-R-3024CRV
30" X 24" 15' Radius10 lbs. (4 kg)109
ACC-R-ANCHAnchor Assembly50
BIT-T27T-27 tamper Proof Torx® Bit5

Replaceable Cast in Place Physical Characteristics

ASTM ReferenceTest DescriptionTest Results
ASTM D 695Compressive Strength26,900
ASTM D 790Flexural Strength31,300
ASTM D 570Water Absorption0.05%
ASTM C 1028Slip Resistance1.18 Dry / 0.88 wet
ASTM E 84Flame Spread Index<= 25
ASTM B 117Salt SprayNo Change (300 hours)
ASTM 1308Chemical StainNo Effect
ASTM C 501Abrasion Resistancelw >500
ASTM G 155Accelerated WeatheringDelta E <5 (2,000 hours)
ASTM D 638Tensile Strength12,800 psi
AASHTO-H20Load Bearing at 10,410 lbsNo Cracking, Delamination or Deformation
ASTM C 1026Freeze/Thaw/HeatNo Chipping, Cracking, or Peeling
ASTM D 1037Accelerated Aging (Freeze/Thaw)No Changing in Color, Gloss or Delamination
ASTM D 696-03Linear Thermal Expansion9.45×10-7 per ºFahrenheit
RCRA-CNon-Hazardous ClassificationNon-Hazardous

Replaceable Cast in Place Technical drawing

Product Size1'X1'2'x2'2'x3'2'x4'2'x5'3'x4'3'x5'Radius
PDF1'x1' cast in place technical drawings pdf2'x2' cast in place technical drawings pdf2'x3' cast in place technical drawings pdf2'x4' cast in place technical drawings pdf2'x5' cast in place technical drawings pdf3'x4' cast in place technical drawings pdf3'x5' cast in place technical drawings pdfradius cast in place technical drawings pdf
DWG1'x1' cast in place technical drawings autoACD2'x2' cast in place technical drawings autoACD2'x3' cast in place technical drawings autoACD2'x4' cast in place technical drawings autoACD2'x5' cast in place technical drawings autoACD3'x4' cast in place technical drawings autoACD3'x5' cast in place technical drawings autoACDradius cast in place technical drawings autoACD

Surface Applied Tiles

Surface Applied Specifications

Part No.Standard SizesWeightBox QuantityAnchors
ACC-S-1212-XX1' X 1'2 lbs. (1 kg)164
ACC-S-2424-XX2′ X 2'8 lbs. (4 kg)166
ACC-S-2436-XX2' X 3'10 lbs. (5 kg)168
ACC-S-2448-XX2′ X 4′13 lbs. (6 kg)168
ACC-S-2460-XX2' X 5'16 lbs. (7 kg)1610
ACC-S-3648-XX3′ X 4′20 lbs. (9 kg)1612
ACC-S-3660-XX3' X 5'27 lbs. (12 kg)1615
ACC-S-3024-CRV

30" X 24" 15' Radius8 lbs. (4 kg)1616
ACC-S-ANCH-XXAxius® Fasteners50
TBS-010Tactile Bond & Seal12

Surface applied Physical Characteristics

ASTM ReferenceTest DescriptionTest Results
ASTM D 695Compressive Strength26,900
ASTM D 790Flexural Strength31,300
ASTM D 570Water Absorption0.05%
ASTM C 1028Slip Resistance1.18 Dry / 0.88 wet
ASTM E 84Flame Spread Index<= 25
ASTM B 117Salt SprayNo Change (300 hours)
ASTM 1308Chemical StainNo Effect
ASTM C 501Abrasion Resistancelw >500
ASTM G 155Accelerated WeatheringDelta E <5 (2,000 hours)
ASTM D 638Tensile Strength12,800 psi
AASHTO-H20Load Bearing at 10,410 lbsNo Cracking,Delamination or Deformation
ASTM C 1026Freeze/Thaw/HeatNo Chipping, Cracking, or Peeling
ASTM D 1037Accelerated Aging (Freeze/Thaw)No Changing in Color, Gloss or Delamination
ASTM D 696-03Linear Thermal Expansion9.45×10-7 per ºFahrenheit
ASTM C 1583Tile Bond StrengthPassed
RCRA-CNon-Hazardous ClassificationNon-Hazardous

Surface applied Technical drawing

Product Size1'X1'2'x2'2'x3'2'x4'2'x5'3'x4'3'x5'Radius
PDF1'x1' surface applied technical drawings pdf2'x2' surface applied technical drawings pdf2'x3' surface applied technical drawings pdf2'x4' surface applied technical drawings2'x5' surface applied technical drawings pdf3'x4' surface applied technical drawings pdf3'x5' surface applied technical drawings pdfsurface applied radius curve technical drawings pdf
DWG1'x1' surface applied technical drawings autoCAD2'x2' surface applied technical drawings autoCAD2'x3' surface applied technical drawings autoCAD2'x4' surface applied technical drawings autoCAD2'x5' surface applied technical drawings autoCAD 3'x4' surface applied technical drawings autoCAD3'x5' surface applied technical drawings autoCADsurface applied radius curve technical drawings autoCAD

Footer

PRODUCTS | ADA RESOURCES | TACTILE GALLERY | TESTIMONIALS | FAQ | CONTACT

ACCESS® TILE • 241 Main Street, Suite 100 • Buffalo, NY 14203 • Phone: 1-888-679-4022

ACCESS® TILE • 1104 Corporate Way, Unit 105 • Sacramento, CA 95831 • Phone: 1-916-361-6545

AccessTile.com is the official website for Access® Tile in the USA

Kinesik is our Official Canadian Distributor. Visit: Access® Tile Canada

Access Products INC
Access Tile TActile System
Access Plus
Ecoglo
Trip Stop
© 2021 ACCESS® TILE All Rights Reserved. Privacy policy | Terms & Conditions
Access Tile Tactile System
  • Products
    ▼
    • Replaceable Cast In Place
    • Surface Applied
    • Wayfinding
    • Radius Curve
    • Product Warranty
    • Quote Request
  • ADA Resources
    ▼
    • Radius Calculator
    • ADA Regulations
    • Specifications & Technical
    • Installation & Maintenance
    • Material Safety Data Sheets
    • Catalog
    • Submittal Package
    • Certificates
    • Warranty
    • Blog
  • Tactile Gallery
    ▼
    • Replaceable Cast in Place Gallery
    • Surface Applied Gallery
    • Wayfinding Tiles Gallery
    • Radius Curve Gallery
  • Testimonials
  • FAQ
    ▼
    • The Top 20 FAQ
    • ADA Curb Ramps
    • Affordable tactile
    • Non-Slip Tactile
    • Benefits
    • High Definition
    • Trip Hazard Protection
    • Truncated Dome Spacing
  • Contact
    ▼
    • Our Locations
    • Distributors